Products
|
  |
Laser triangulation
position sensors
RF60X Series
Application
domain
The sensors are intended
for measuring and checking of
position,
dimensions,
surface profile,
deformation, vibrations,
sorting and sensing of
technological objects as well as for measuring levels of
liquid and bulk materials.
The series includes three lines of models:
RF603 -
quick-response sensors with 2 to 1000 mm operating range,
RF600 – large-base sensors and
RF605 –
inexpensive compact sensors.
Operating principle
Operation of the sensors is based on the principle of optical
triangulation.
Radiation of a semiconductor laser 1 is focused by a lens 2
onto an object 6. Radiation reflected by the object is
collected by a lens 3 onto a linear CCD-array 4. A signal
processor 5 calculates the distance to the object from the
position of the light spot on the array 4. |
 |
RF603 Model. Performance specification
|
RF603 - |
R-X/4 |
X/2 |
X/5 |
X/10 |
X/15 |
X/25 |
X/30 |
X/50 |
X/100 |
X/250 |
X/500 |
X/750 |
X/1000 |
 |
|
Base distance, X, mm |
39 |
10 |
15 |
15,25 60 |
15,30 65 |
25,45 80 |
35,55 95 |
45,65 105 |
60,90 140 |
80 |
125 |
145 |
245 |
|
Measuring range, L, mm |
4 |
2 |
5 |
10 |
15 |
25 |
30 |
50 |
100 |
250 |
500 |
750 |
1000 |
|
Linearity |
±0.2% |
±0.1% of the range |
±0.2...0,3 |
|
Resolution |
0,01% of the range |
0.03 |
|
Max Sample Rate, kHz |
2 or 5 or 8
or 9,4 |
|
Laser type |
1 mW,
wavelenth 660 íì,
Class 2 |
3R |
|
Interface |
digital |
RS232 (max 460,8 kbit/s) or RS485
(max 921,6 kbit/s) or
CAN (max 1 Mbit/s)
and RS232 or
Ethernet and RS232 |
|
analog |
4...20 mA or 0...10 V |
|
Synchronization Input |
2,4-5 V (CMOS,
TTL) |
|
Alarm Output |
NPN: 100 mA max; 40 V max |
|
Power Supply, V |
5
(±5%)
or
9…36 |
|
Power Consumption, W |
1,5...2 |
|
Enclosure rating |
IP67 |
|
Operating temperature, °Ñ |
-10…+60 |
|
Size, mm |
65x50x20 |
|
Weight, g |
90 |
RF600 Model. Performance specification |
|
|
RF600- |
230/250 |
300/500 |
230/600 |
350/1000 |
1300/1000 |
380/2000 |
 |
|
Base distance, mm |
230 |
300 |
230 |
350 |
1300 |
380 |
|
Measuring range, mm |
250 |
500 |
600 |
1000 |
1000 |
2000 |
|
Linearity |
±0.1%..0.15% of the range |
±0.2%..0.3%
of the range |
|
Resolution |
0,01% of
the range |
0,05% of
the range |
|
Max Sample Rate, Hz |
2000 |
8000 |
2000 |
|
Laser type |
5 mW, 660 íì,
Class 3R |
|
Interface |
digital |
RS232 (max 460,8 kbit/s) or RS485
(max 921,6 kbit/s) or
CAN (max 1 Mbit/s)
and RS232 or
Ethernet and RS232 |
|
analog |
4...20 mA or 0...10 V |
| Synchronization
Input |
2,4-5 V (CMOS,
TTL) |
|
Alarm Output |
NPN: 100 mA max; 40 V max |
|
Power Supply, V |
5
(±5%)
or
9…36 |
|
Power Consumption, W |
1,5...2 |
|
Enclosure rating |
IP67 |
| Operating temperature, °Ñ |
-10…+60 |
|
Size, mm |
63x170x30 |
|
Weight (without cable), g |
500 |
Downloads
|
|
|
|
RF605 Model. Performance specification |
|
|
RF605- |
25/50 |
45/100 |
65/250 |
105/500 |
 |
|
Base distance, mm |
25 |
45 |
65 |
105 |
|
Measuring range, mm |
50 |
100 |
250 |
500 |
|
Linearity |
0.3% of the range |
|
Resolution |
0,1% of
the range |
|
Max Sample Rate, Hz |
2000 |
|
Laser type |
<1 mW, 660 íì,
Class 2 |
|
Interface |
digital |
RS232 (max 460,8 kbit/s) or RS485
(max 460,8 kbit/s)
|
|
analog |
4...20 mA or 0...10 V |
| Synchronization
Input |
2,4-5 V (CMOS,
TTL) |
|
Alarm Output |
NPN: 100 mA max; 40 V max |
|
Power Supply, V |
24 (9…38) |
|
Power Consumption, W |
1 |
|
Enclosure rating |
IP67 |
| Operating temperature, °Ñ |
-10…+60 |
|
Size, mm |
50x50x17 |
|
Weight (without cable), g |
60 |
Downloads
|
|
|
|
Options
- build-in heater for operation at low
temperatures;
- protective housing with air cooling
- digtal display of RF30X Series
for connection of sensors;
Characteristics of sensors can be customised to a
specific task. |
|
 |
|
Products
:: Company Information
:: Download
:: Price-list
:: Distributors
:: Feedback
|
|
RIFTEK, 22, Logoiski trakt,
220090, Minsk, Republic of Belarus Tel./fax +375 17281-35-13,
+375 17 281-36- 57, tel +375 29