Automated laser systems for alignment of turbo-sets |
The systems are designed for automation of works
in alignment and accurate positioning of assemblies
and mechanisms, in particular, for alignment of turbo-set
assemblies in the course of repairs carried out at heat
power plants.
Measurement error:
0,01 mm on 20 m
0,2 mm on 50 m
Measurement range:
±25 mm (vertical)
±10 mm (horizontal) |
|
|
|
Gauges with partial part straddling
IDV-1 Series |
The gauges are designed for measuring/gauging of diameters of
shafts, in particular, in the course of repairing of turbine
equipment. Use of the gauges eliminates the necessity of raising the
shafts to be repaired thus increasing cost-efficiency and
productivity.
Range
custom
Error
±0.01 um |
|
|
|
|
Calliper gauges
IDV-2 Series
|
The devices are designed for measuring external diameter of
cylindrical parts.
Measuring range custom
Error
±0.002 um |
|
|
Flame control equipment for oil- and gas-fired
boiler burners
Plamya-01 Series
|
|
The equipment is designed for monitoring burning processes in oil- and
gas-fired boilers. Photoelectric sensors are directed at burner flames in a boiler
unit. Optical signal taken in the UV and visible range from the
burner flame is converted into electrical signal and digitized. The
alarm unit (warning device) performs flame body assessment and forms
relay signals for boiler control system.
|
|
|
System for control of thermally induced displacements.
|
|
The system is designed for automatic control and registration of thermally
induced displacement processes occurring via keyed joint clusters and slip
surfaces of high-power turbine components for the purpose of detecting
intolerable deviations and localization of defects. |
Performance characteristics:
|
|
Number of measurement channels |
16 |
|
Linear displacement measurement range, mm |
10, 50 |
|
Type of used sensors |
RF20X Series |
|
Detection time interval, min |
120 |
|
|
Техническое описание, инструкция по эксплуатации |
.pdf (320 kb) |
|
|